FUJIFILM SonoSite M-Turbo
seed_demo: impact history
- Supply
- 100–240 V
- Frequency
- 50/60 Hz
- Draw
- 75 VA
- Rated for
- 10–40 °C
- Humidity
- to 95%
Do not ship
1 blocker, 2 conditions
A screen, not a clearance. A person decides before anything ships.
Hopital Communautaire de Pignon Haiti
110 V 60 Hz wards to 36.0°C 12 outages a week
1 blocked
2 conditional
5 unanswered
7 clear
What blocks it
- Training and repair. A high-skill device, and Hopital Communautaire de Pignon has no biomedical technician on site.
Still missing, even if you solve that
- A voltage stabiliser
- A handover packet in French, built from the manufacturer's manual.
Answer these and the screening sharpens
- Is there a supplier for acoustic coupling gel (Aquasonic recommended; other gels can damage transducers), sterile transducer sheaths and sterile gel for invasive/surgical use, printer paper (Sony, for optional B/W or color printer), Li-ion battery (six cells), external power supply 15 V / 12 V DC, transducers (C60x, C60xi, HFL38x, L38x, P21x etc.) in Haiti?
- Can spare parts for FUJIFILM SonoSite M-Turbo be bought in Haiti?
- What year was the device made? The nameplate usually prints it next to the serial number.
- What are Haiti's import and registration rules for donated medical equipment?
- Does anything being sent carry an expiry date - sterile circuits, filters, reagents, batteries? If so, what is the earliest?
Audit trail — 15 checks
Every row is decided by code, not by a model. The tag on the right says where the fact came from, which is the only part a model touched.
| Check | Finding | What would fix it | Fact from | Status |
|---|---|---|---|---|
| Training and repair | A high-skill device, and Hopital Communautaire de Pignon has no biomedical technician on site. | Hopital Communautaire de Pignon would need operators trained on commissioning, and a service contract or a named regional technician, before this could run. | spec sheet | FAIL |
| Grid reliability | 12 outages a week. Switching transients kill power supplies in equipment that assumes a steady feed. | A voltage stabiliser | clinic profile | MITIGABLE |
| Manual language | The manual is in English, German; staff read French, Haitian Creole. Fit-Check generates a handover packet in French from the manufacturer's manual. | A handover packet in French, built from the manufacturer's manual. | spec sheet | MITIGABLE |
| Consumables | Needs acoustic coupling gel (Aquasonic recommended; other gels can damage transducers), sterile transducer sheaths and sterile gel for invasive/surgical use, printer paper (Sony, for optional B/W or color printer), Li-ion battery (six cells), external power supply 15 V / 12 V DC, transducers (C60x, C60xi, HFL38x, L38x, P21x etc.). Whether these sell in Haiti is not known. | Is there a supplier for acoustic coupling gel (Aquasonic recommended; other gels can damage transducers), sterile transducer sheaths and sterile gel for invasive/surgical use, printer paper (Sony, for optional B/W or color printer), Li-ion battery (six cells), external power supply 15 V / 12 V DC, transducers (C60x, C60xi, HFL38x, L38x, P21x etc.) in Haiti? | unknown | NEEDS INFO |
| Spare parts | Whether parts for FUJIFILM SonoSite M-Turbo can be sourced in Haiti is not known. | Can spare parts for FUJIFILM SonoSite M-Turbo be bought in Haiti? | unknown | NEEDS INFO |
| Age and support | The device's age is not known. | What year was the device made? The nameplate usually prints it next to the serial number. | unknown | NEEDS INFO |
| Import and registration | No import and registration rules for Haiti are on file. | What are Haiti's import and registration rules for donated medical equipment? | unknown | NEEDS INFO |
| Shelf life on arrival | No expiry date recorded for this consignment. | Does anything being sent carry an expiry date - sterile circuits, filters, reagents, batteries? If so, what is the earliest? | unknown | NEEDS INFO |
| Supply frequency | Rated 50/60 Hz, and the grid is 60 Hz. | — | spec sheet | PASS |
| Supply voltage | Rated 100-240 V, which covers the 110 V grid. | — | spec sheet | PASS |
| Operating temperature | Rated to 40 C, and rooms reach 36 C. | — | spec sheet | PASS |
| Humidity | Rated to 95 % and the site reaches 90 %. | — | spec sheet | PASS |
| Medical oxygen | The device does not need medical oxygen. | — | spec sheet | PASS |
| Distilled water | The device does not need distilled water. | — | spec sheet | PASS |
| Compressed air | The device does not need compressed air. | — | spec sheet | PASS |
Saved as /verdict/6b77e572